Home About us Products Contact us Distributors
|
CHY-001compteur de particules de l'air
1CFM Particle counterDetailed content
|
Sampling Volume |
28.3L/min (1Cfm) |
Test Size |
0.3,0.5,1,3,5,10um |
Self-purification Time |
≤10min |
Error of Particle Size |
0.5um 5um ≤±30% |
Error of Concentration |
0.5um ≤±30% |
Deflection of Measurement |
≤±10% |
Communication Interface |
RS232 |
Max Communication Speed |
9600BPS |
Light Source |
Import laser diode(using hour>30000 hours) |
Power Source |
AC220V±5% 50HZ |
Weight |
10Kg |
Overall Size |
450×270×150(L×W×H)mm |
Service Environment |
Working Environment:15~35℃, 10-85%RH |
Adjustment Standard |
Storage Environment:-10~50℃, 10-85%RH |
GB/T6167-2007 and particulate counter performance test standard |
|
Clean Class Estimate Standard |
JJF-1190-2008 particulate counter standard |
ISO14644 FS209E , New GMP(dynamic/static) |
Functions
Sampling Period |
1~99s user set |
Sampling Delay |
≤99s |
Test Interval |
≤999s |
Sampling Type |
Singleness、≤99times(set)、continuous |
Data Storage |
1000 Record |
Sampling Location |
1000 Group |
Counting Type |
Cumulative count, fig2.open-window |
Alarm Class |
Class100 ~ Class300,000 class(FED209E Standard) |
Or 5 ~ 9level(ISO14464-1Standard) |
|
Display Type |
LCD big screen |
Print Type |
Built-in temperature-sensitive printer |
Display |
LCD display,Slope interface,convenient for detecting |
Press Key |
Functional module interface,fast into detectiong system |
Test Stardard |
GB/T6167-2007 JJF1190-2008 |
Clean Class Estimate Standard |
ISO14644 FS209E |
Standard Accessories |
Built-in reset filter,isokinetic samping probe,tripod,portable protection case,operation instruction,adjust report,printer. |
Optional Accessories |
External humiture sensor,Data analysis software optical disk and data line. |
Sevice Environment:
Normal atmosphere, No stange magnetic field
Power Source:A.C220V±5%
50HZ
Standard Accessories:
1.Isokinetic
sampling
,imported
anti-static sampling tube,tripod;
2. Self-purification filter;
3,Temperature-sensitive
printing paper 2 pcs
4. Printer
5,Factory
calibration report,packing
list,operation
instruction;
Optional Accessories
1. Data analysis software
2. Humiture sensor
3. Data line
Features:
Using import semiconductor laser tube and import semiconductor
photosensitive tube,assure sensitivity and response speed.
Using import micropump,assure
samping volume steady,reduce
noise.
The key component-light scattering sensor obviously eliminate
intracorporal stray light,improve SNR, test result more precise and
reliable.The light scattering sensor got Chinese patent.
Confidence meansurement of this instrument,According
to GB/T6167-2007 Standard,realize
auto estimate clean class,creatively to auto estimate ≤9 location points
clean class.
1000 records stored,free to check previous data.User can optional PC
data analysis sofeware,realize data managerment.
User can chose humiture sensor(optional accessories).
Samping volume display as digit,more intuitive and precise.
“Measurement Number”function,realize
multipoint managerment.
Lithium battery,more
safety,continuous
working 6 hours.
Meets JJF-1190-2008 particulate counter standard
Self-purification time≤10min
Deflection of measurement≤±10%
Error of particulate size 0.5um 5um≤±30%
Error of concentration 0.5um≤±30%
Samping volume and error:2.83L/min
≤±5%
Range of size channel:0.3,0.5,1,3,5,10um,6
channels,0.3um
SNR≥2.5:1
Max concentration:≤300,000/L
Power DC7.2V,1800mAh.
Performance parameter:
Particle Size |
0.3, 0.5,1,3,5,10μm |
Light Source |
Laser diode(using hour>30000 hours) |
Flow |
2.83 L /min(0.1cfm) |
Counting Rate |
50±10%@0.3μm, 100±10%@0.5μm |
Deflection of Measurement |
≤±10% |
Samping Time |
User set (1~99min) |
Samping Delay |
User set (1~99min) |
Samping Rate |
1~99times or continuous |
Alarm Class |
Class10~ Class300,000 class(FED209E Standard)or 2~ 9class (ISO14464-1 standard) |
Test Type |
Singleness/Repeat/Continuous/Timing/Average |
Data Storage |
1000 records |
Error Indicator |
Exceed storage,laser died,exceed adjusted flow(>±5%),battery died |
Communication Interface |
USB、RS232 |
Max Communication Speed |
12MBPS |
Charging Time |
3hours,first time 12hours |
Self-purification |
≤10min |
Concentration limit |
"+/-5% at 2000000 particles/ft3 (71000 Particle/L) |
Display Type |
LCD big screen |
Print Type |
External printer,Epson ribbon |
Sampling Location |
1000 group |
Counting Type |
Cumulative counting,region |
Power Source |
Chargeable Ni-MH battery(6V/2500mAH)or AC adapter(input 100~240V) |
Battery working hour |
Continuous working > 6 hours |
Overall Size |
125*43*230mm |
Weight |
0.98kg |
Environmental Conditions |
Working Environment: 15~35℃, 10-85%RH;Storage Environment:-10~50℃, 10-85%RH |
Standard Accessories |
AC adapter,battery charge,reset filter,isokinetic sampling probe,tripod,portable protection case,operation instruction,adjust report,printer |
Optional Accessories |
External humiture sensor,Data analysis software optical disk and dataline |
Test Standard |
JIS-B-9921(1997), ASTM-F649-01, ASTM-F328-98 (NIST traceable) JJG547-1988 GB/T6167-2007 JJF1190-2008 |
UCL Estimate Sandard |
ISO14644 FS209E |
Summarize:
Using imported semiconductor laser and photosensitive tube;
The key component-light scattering sensor obviously eliminate
intracorporal stray light,improve SNR, test result more precise and
reliable.The light scattering sensor obtained Chinese patent.
Confidence meansurement of this instrument,meet
GB/T6167-2007 and JJG547-88 Standard,realize
auto estimate clean class.
600 records stored,free to check previous data.PC communication
interface.
Humiture sensor interface, connect with (optional accessories )humiture
sensor can test humiture.
Features:
Style |
CHY002 Laser big screen |
Standard |
JJF1190-2008 |
Air volume |
2.83 L /min(0.1cfm) |
Size channels |
0.3, 0.5,1,3,5,10μm |
Error of particle size |
≤±30% |
Error of concentration |
≤±30% |
Repeatability |
≤±10% |
Self-purification time |
≤10min |
Light source |
Laser diode(Using hour>30000hours) |
Power source |
AC 220V 50Hz |
Weight |
3.6kg |
Overall size |
270*210*120mm |
Service environment |
Working environment:15~35℃, 10-85%RH |
Store environment:-10~50℃, 10-85%RH |
|
Clean Class estimate Standard |
ISO14644 FS209E |
Functions
Style |
CHY002 Laster big screen |
Sampling type |
1~991~99 times or continuous |
Working time |
Continuous working 6 hours |
Data storage |
600 records |
Counting type |
Cumulative count, fig2.open-window |
Alarm class |
1 ~ 100,000 class(FED209E Standard) |
Or 2~ 9class (ISO14464-1 Standard) |
|
Display type |
LCD big screen |
|
Built-in printer |
Error indicator |
Exceed Max record,Laser died, |
Exceed adjust flow(>±5%)。 |
|
Test standard |
GB/T6167-2007 JJF1190-2008 |
Clean Class estimate Standard |
ISO14644 FS209E |
Standard accessories |
Power line,reset filter, |
Isokinetic sampling probe,tripod,portable protection case, |
|
Operater instruction,adjust report, printer |
|
Optional accessories |
N/A |
Features:(Meet JJF1190-2008 particle counter standard)
1. Self-purification: ≤10min
2. Repeatability:≤±10%FS
3. Error of particle size:≤±30%
4. Error of particle concentration:≤±30%
5. Error of air volume:2.83L/Min≤±5%
6. Safety:Insulation Resistance>20M (Normal atmosphere)
Other parameter:
1. Power source:220VAC±10%50HZ
2. Max particle concentration:≤300,000/2.83L
3. Size channels:0.0.10(um)
4. Range of purification class:100~300000 Class
5. Overall Size:270×210×120mm (L×W×H)
6. Weight:3.5KG
Environmental Conditions:
1. Temperture:5℃—35℃
2. Humidity:RH≤75%
3. Normal atmosphere,cleanroom
Others
1. Built-in printer,auto-printer
test report.
2. Instruction,certification of inspection,Test report,guarantee
card,tripod,printing paper,easy to use.Aluminium alloy
package,portable,detachable-retractable measuring tube.
Summarize:
1.Using imported semiconductor laser and photosensitive tube,assure
sensitivity and response speed.using imported micropump,assure flow
steady.
2.The key component-light scattering sensor obviously eliminate
intracorporal stray light,improve SNR, test result more precise and
reliable.
3.Confidence meansurement of this instrument is the only one in China
meet GB/T16292-194896, realize auto estimate clean class.
4.1000 records can be stored,free to check previous data.PC
communication interface.
5.Humiture sensor interface,connect with (optional accessories )humiture
sensor can test humiture.
6.AC/DC power,bulit-in battery and rechargeable,working continuously 6
hours.
7.Stainless steel,LCD
display,smart,light,beautiful,portable,long-service time
8.Our company using American Royco’s particle counter adjust device and
Duk’s standard particle,assure each product got strict inspection before
leave factory,quality is guaranteed.
Service Environment:
Particle concentration limit 400,000/L
Normal atmosphere No strong magnetic field
Power source:A.C220V±5% 50HZ
Features:
Size channels |
0.3, 0.5,1,3,5,10μm |
Light source |
Laser diode(using hour>30000hours) |
Flow |
2.83 L /Min(0.1cfm) |
Deflection of measurement |
≤±10% |
Error of particle size |
0.5um 5um≤±30% |
Error of concentration |
0.5um≤±30% |
Sampling time |
User set (1~99min) |
Sampling delay |
User set (1~99min) |
Sampling rate |
1~99 times or continuous |
Alarm class |
Class100 ~ Class300,000(FED209E Standard)or 5 ~ 9(ISO14464-1) |
Test type |
Singleness/Repeat/Continuous/Timing/Average |
Data storage |
1000 records |
Error indicator |
Exceed storage,laser died,exceed adjusted flow(>±5%),battery died |
Communication interface |
USB、RS232 |
Max communication speed |
12MBPS |
Charging time |
3hours,first time 12hours |
Self-purification time |
≤10min |
Concentration limit |
"+/-5% at 2000000 particles/ft3 (71000 Particle/L) |
Display |
LCD big screen |
|
Built-in printer,Epson ribbon |
Sampling location |
1000 group |
Counting type |
Cumulative counting,region |
Power source |
Rechargeable lithium battery(7.4V/5200mAH)or AC adapter(100~240V) |
Battery working time |
Continuous working> 6 hours |
Overall size |
220*285*140mm |
Weight |
3.6kg |
Rinch Industrial Co.,Limited
Address: Room302, Bldg 17, No. 35 Dedu road, Baoshan, Shanghai China Zip code: 200941
Tel: 86-21-36300944 Fax:86-21-36300944 Msn:goodluckvon@hotmail.com email: cnrinch@gmail.com goodluckvon@hotmail.com