RC-MW Halogen moisture analyzer use heating method to test the moisture
content of the test sample, it can test moisture content fast. And the result
similar as the oven test standard, so it wildely used in different industry.
Such as agriculture,medicine,plastic etc
Use halogen moisture analyzer should attention:
1,halogen moisture analyzer is used to measure the moisture content in the
sample,
used for any other purpose are likely to cause harm and personal damage the
instrument.
2, Please read the instructions carefully before you use it, do not use it under
the environment
condition which not meet the requirements.
3, halogen rapid moisture analyzer only suit for professional operate.
4, halogen rapid moisture analyzer for power for the three plug with earthing
socket,
banned disconnect apparatus grounding or use without a good grounding power
supply.
5, Instrument around should ensure that there is enough space, so as to avoid
heat accumulation and heat.
6, Please do not put flammable and explosive goods around the instrument.
7, After the test, the heating unit and the container is still very hot, so
please do not touch it.
8, Toxic substances testing should be under ventilation environment
|
§Ñ§ß§Ñ§Ý§Ú§Ù§Ñ§ä§à§â §Ó§Ý§Ñ§Ø§ß§à§ã§ä§Ú §Ô§Ñ§Ý§à§Ô§Ö§ß§ß§í§Û
PARAMETERS |
MODEL |
RC105MW |
RC102MW |
RC100MW |
RC100MW-T |
SPECIFICATION |
110g/5mg |
110g/2mg |
110g/1mg |
110g/1mg |
SENSOR |
LOADCELL |
PANSIZE |
Φ90mm |
READABILITY |
5mg |
2mg |
1mg |
1mg |
OPERATING TEMP.RANGE |
5¡ãC—35¡ãC |
HEAT SOURCE |
HALOGEN LAMP-1 |
HALOGEN LAMP-2 |
TEMP SENSOR |
PT-100 |
PT-100 |
TEMP RANGE |
40¡ãC—199¡ãC |
40¡ãC—199¡ãC |
TEMP STEP |
1¡ãC |
1¡ãC |
MOISTURE RANGE |
0.00%—100.00% |
|
MOISTURE READABILITY |
0.10% |
0.04% |
0.01% |
0.01% |
DRY RANGE |
100.00%—0.00% |
100.00%—0.00% |
DRY READABILITY |
0.10% |
0.04% |
0.01% |
0.01% |
ATRO |
100%....999% |
100%....999% |
ATRO |
0%....999% |
0%....999% |
NUMBER OF STORAGE |
15 |
20 |
MOQ |
10pcs |
5pcs |
|
|
RC-100MW-T Series §Ñ§ß§Ñ§Ý§Ú§Ù§Ñ§ä§à§â §Ó§Ý§Ñ§Ø§ß§à§ã§ä§Ú §Ô§Ñ§Ý§à§Ô§Ö§ß§ß§í§Û |
Mode |
RC-100MW-T |
Range (g) |
110g |
Readability(g) |
0.001g |
Operating Temp |
5℃-35℃ |
Pan Size |
Ø 90mm |
|
Heat Source |
Halogen Lamp |
Temp.Sensor |
PT 100 |
Temp. Range |
40℃-199℃ |
Temp.Step |
1℃ |
|
Moisture Range |
0.00%-100.00% |
Moisture Readability |
0.01% |
Dry Residual Range |
100.00%-0.00% |
Dry Residual Readability |
0.01% |
|
Temp Setting |
40℃-199℃ By 1℃ Step |
Time Setting |
1-99min by 10 s |
|
Number Of Storage |
20 |
Number Of History |
20 |
|
Heater |
220V ¡À15% 50HZ
400W |
Balance |
Input: 220V 50HZ
Output:9V |
|
Host Dimension |
360X490X350mm |
The Chamber Height |
22mm |
|
Display |
5 inch touch panel |
Calibration |
External Calibration |
Interface |
RS232 |
¡¡ |
|
RC-MS Series §Ñ§ß§Ñ§Ý§Ú§Ù§Ñ§ä§à§â §Ó§Ý§Ñ§Ø§ß§à§ã§ä§Ú §Ô§Ñ§Ý§à§Ô§Ö§ß§ß§í§Û Functions:
1. Automatic open the heating chamber. Keep the weighing and test more
stable.
2. 7 inch HD display,moisture analysis curve,moisture content%/dry
weight %/dry weight direct display;
3. 40-230℃ limit heating temperature;
4. The test hight 35cm ;
5. The window can look the test sample;
6. 20 groups of setting address;
7. 20 groups of history can check and print;
8. Max weight can choose 200g;
9. HBM weighing sensor;
10. 4 sets of stainless steel;
11. The special material case suit for high temperature test;
12. Appearance and structure to obtain a number of patents;
13. Easy cleaning for open test chamber;
14. Easy fix and repair design;
15. Intelligen system can protect operation not crush by machine;
16. New system update easily.
RC-MS Series
§Ñ§ß§Ñ§Ý§Ú§Ù§Ñ§ä§à§â §Ó§Ý§Ñ§Ø§ß§à§ã§ä§Ú §Ô§Ñ§Ý§à§Ô§Ö§ß§ß§í§Û |
Mode |
RC-100MS |
RC-100MS(plus) |
RC-200MS |
RC-200MS(plus) |
Range (g) |
110g |
210g |
Readability(g) |
0.001g |
0.001g |
Operating Temp |
5℃-35℃ |
Pan Size |
Ø100mm |
|
Heat Source |
Halogen Lamp |
Temp.Sensor |
PT 100 |
Temp. Range |
40℃-230℃ |
Temp.Step |
1℃ |
|
Moisture Range |
0.00%-100.00% |
Moisture Readability |
0.01% |
Dry Residual Range |
100.00%-0.00% |
Dry Residual Readability |
0.01% |
ATRO |
100%-999% |
ATRO |
0%-999% |
|
Temp Setting |
40℃-230℃ By 1℃ Step |
Time Setting |
1-99min by 10 s |
|
Number Of Storage |
20 |
Number Of History |
20 |
|
¡¡
Heater |
220V ¡À15% 50HZ/
110V¡À15% 60HZ
400W |
¡¡
Balance |
Input: 220V 50HZ/110V 60HZ
Output:9V |
¡¡
Machine |
Input: 220V 50HZ/110V 60HZ
Output:24V
(Dual-drive) |
|
Host Dimension |
215X195X415mm |
Indicator Dimension |
200X75X135mm |
Operation Height |
275mm |
The Chamber Height |
35mm |
|
Display |
7 inch touch panel |
Interface |
RS232/RJ45/USB... |
Communication Mode |
Cable |
Wireless |
Cable |
Wireless |
Rechargeable Battery |
No |
10,000mAh |
No |
10,000mAh |
|
Calibration |
External Calibration |
|