| HLD-200 Halogen leak detector is a newly high performance intelligent halogen leak detector. The new shell designed with LED displaying is elegant, easily-carried, easy operation, visual and clear display, etc. ¡¡ Features: Visual display and single light diode displays the leak degree in large range in the form of "gradually lights the light". Providing 6 levels of sensitivity to set the real-time cycle adjustment Easy operation with pushbutton Battery checked function with tricolor display Detect all kinds of halogenated refrigerants. The high effective true mechanical pumping provides positive airflow through sensing tip, which can improve the sensitivity and response speed. Applicable areas: 1 The leak-detect in vocation of freeze, refrigeration, and air-conditioner 2 The leak-detect for air-conditioner in the car 3 It will respond to all halogen gases (including Chlorine and Fluorine). Including CFCS e.g. R12, R11, R500, R503 etc. HCFCS e.g. R22, R123, R124, R502 etc HFCS e.g. R134a, R404a. R125 etc. And other mixtures, e.g. AZ-50, HP62, MP-39, etc. 4 Detect Ethylene Oxide gas leaks in hospital sterilizing equipment (it will detect the homogenate carrier gas. 5 Detect SF-6 in high voltage circuit breaks 6 Detect most gases including Chlorine, Fluorine and Bromine (halogen gas) 7 Detect cleaning agents used in dry cleaning applications such as perchloroethyl. 8 Detect halogen gases in fire-extinguishing system. Specification and parameters: Power supply: 3VDC (2XAA battery) Max. Sensitivity: R12, R22, R134a are certified to 7g/yr Probe life: about 30h ¡¡ |
large photo | CPU-1G Halogen leak detector General descriptions: We are proud to present this tool as the most stable and sensitive negative corona leak detector ever made. We have incorporated all of our experience and years of customer feedback into our product, in the hope of providing our valued customers with the best of everything: price, performance and reliability. An advanced microprocessor is the heart of this unit. Its digital processing permits better management of circuitry and sensing tip signal than ever before possible. Additionally, the number of components used in the circuit is reduced nearly 40%, increasing reliability and performance. The microprocessor monitors the sensing tip and battery voltage levels 4000 times per second. Compensating for even the most minor fluctuations in signal. This translates into stable and dependable tool in almost any environment. Convenience features have been added to enhance the usability of the CPU-1G. Seven levels of sensitivity provide an increase of 64 times from level 1 to level 7. Unique Tri-Color LED¡¯s show a progressive and wide ranging leak size indication, communicate the sensitivity level, and provide a true voltage indication of battery power level. A tactile keypad controls all functions of operation. A revolutionary new case design gives the user grip a control, and places the visual indicators in direct sight during use.
Features: Microprocessor control, with advanced digital signal processing Tricolor visual display Seven levels of sensitivity provide an increase of up to 64 Tactile keypad controls Real time sensitivity adjustment Battery test function Battery voltage indication Detect ALL halogen refrigerants True mechanical pumping provides positive airflow through sensing tip Mute feature included Cordless and portable, operates on 2 cell batteries Carrying case included Flexible and stainless probe Optional carrying holster Optional reference leak source Two-year warranty
Applications: The CPU-1G leak detector may also used to: Detect leaks in other systems and storage/recovery containers. It will respond to ALL halogenated (contains Chlorine of
Fluorine) refrigerants. This includes, but is not limited to: CFCs e.g. R12, R11, R500, R503 etc HCFCs e.g.R22, R123, R502 etc HFCs e.g.R134a, R404a, R125 etc Blends such as AZ-50 HP62 MP39 etc Detect ethylene oxide gas leaks in hospital sterilizing equipment (it will detect the halogenated carrier gas) Detect SF-6 in high voltage circuit breakers Detect most gases that contain Chlorine, Fluorine, and Bromine (halogen gases) Detect cleaning agents used in dry cleaning applications such as erchloroethyl. Specifications
Power supply: 3V DC, two cell Alkaline batteries Maximum sensitivity: R12,R22,R134a,0.5 oz/yr (14g/yr) Ultimate sensitivity: less than 0.1 oz/yr (3g/yr) for all halogen based refrigerants Sensing tip life: approx. 20hours Operating temperature: 30¨Hto 125¨H(0¡æ to 52¡æ) Battery life: approximately 30 hours in normal use Duty cycle: continuous, no limitation Response time: two second Warm-up time: approximately 6 seconds Unit weight: 560 grams Unit dimensions: 22.9 6.5 6.5cm Fixed probe length: 35.5cm Gross Weight: 1600G/PC Packing: 8 PCS/CTN Measurement of the carton: 57¡Á36¡Á39cm ¡¡ |
| General information: CPU-1F Halogen leak detector The functions of CPU-1F are less than CPU-1G, but its capability and sensitivity change little with high comparability between quality and price. ¡¡ Features: Can be controlled by microcomputer with advanced digital signal processing ability ¡ñ Tri-color display ¡ñ Supply maximum 64 times 7-level sensitivity set ¡ñ Trigger keypad ¡ñ Real time sensitivity adjustable ¡ñ Display battery voltage ¡ñ Detect all halogenating refrigeratingmedium ¡ñ Mechanic pump can supply forward air that passes the sensor ¡ñ Wireless mobile, Size 2 Alkaline batteries(2) ¡ñ 14 inches(35.5cm) soft stainless probe ¡ñ Selective leak source ¡ñ Two years warranty
Application range: ¡ñ Detect halogen leak in lines of refrigeration, cold-storage and air-conditioning ¡ñ Detect halogen Leak in Serial of vehicle-use air conditioners ¡ñ Detect halogen Leak in other systems and storage/recovery vessel.
The product takes effect to all the halogenating refrigeratingmedium with chlorine and fluorine included, which include but are not limited to: CFCs e.g. R12, R11, R500, R503 etc. HCFCs e.g. R22, R123, R124, R502 etc. HFCs e.g. R134a, R404a, R125 etc. It can also detect other mixers such as AZ-50, HP62, MP39, etc. ¡ñ Detect Ethylene Oxide gas leaks in hospital sterilizing equipment(it will detect the homogenate carrier gas). ¡ñ Detect SF-6 in high voltage circuit breakers. ¡ñ Detect most gases that include Chlorine, Fluorine and Bromine (halogen gases). ¡ñ Detect cleaning agents used in dry-cleaning equipment such as carbon tetrachloride. ¡ñ Detect perchloroethyl in fire extinguishing system.
Parameters: ¡î Power supply: DC3V, Size 2 Alkaline batteries(2) ¡î Maximum sensitivity: R12, R22 and R134a have got approved.14g/y ¡î Limit sensitivity: fitting for halogenating refrigeratingmedium 3g/yr ¡î Sensor life expectancy: about 20 hours ¡î Battery life expectancy: About 30 hours under normal condition ¡î Mode: Continous and no limit ¡î Reaction time: Instantaneous ¡î Warm-up time: 6 seconds ¡î Reset time: 2 seconds ¡î Weight: 560g ¡î Size:22.9cm¡Á6.5cm¡Á6.5cm ¡î Length of the probe: 35.5cm Gross Weight: 1575G/PC Packing: 8 PCS/CTN Measurement of the carton: 57¡Á36¡Á39cm |
large photo | HLD-100 halogen leak detector, as the exquisite unit of our company with its feature of higher performance versa lower price, has powerful function and high sensitivity, and is stable and easy to operate.
Features: Detects all kinds of halogenated refrigerants. Single color LED display with 6-level leak alarm. Tricolor display of battery voltage. RESET time sensitivity adjustment. Real time sensitivity adjustment. Adopts quality sensors that can detect slightly leaked halogen gases. 14 inches (35.5cm) flexible stainless steel probe.
Applications: HLD-100 halogen leak detector can also be used in: Other systems and storage/recovery containers The unit responds to all haloge-nated (with Chlorine and Fluorine included) refrigerants. This includes, but is not limited to: CFCs R12, R11, R500, R503etc. HCFCs R22, R123, R124, R502etc. HFCs R34a, R404a, R125etc Detect Ethylene Oxide gas leaks in hospital sterilizing equipment(it will detect the halogenated carrier gas) Detect SF-6 in high voltage circuit breakers. Detect most gases that contain Chlorine, Fluorine, and Bromine (halogen gases) Detect cleaning agents used in dry cleaning applications such as perchloroethyl. Detects halogen gases in fire-extinguishing system.
Specification and Parameter Max Sensitivity:to halogenated refrigerants, 3gr/yr Battery life:30 hours under normal condition Working temperature:0¡æ¡×-52¡æ Working Mode:Continuous and no limit Reaction time :instant Resetting time :2 seconds Warm-up time :about 6 seconds Size: 22.9cm¡Á6.5cm¡Á6.5cm Weight :560 grams Power Supply:3V DV (2 quality batteries) Probe length:35.5cm Gross Weight: 720G/PC Packing: 12 PCS/CTN Measurement of the carton: 57¡Á36¡Á39cm |
| WJL2000 Detect all halogen refrigerants. Manual adjustment of sensitivity, convenient and practical Unique and exquisite electric circuit makes it reliable Sound and light alarming indication Detect minor halogen leak with the adopted excellent sensor Portable design and handbag make it easy to carry Flexible long-probe sensing tips facilitate the detection of leak source in any place
Features: ¡î Power supply DC6V Size 7 battery (4) Maximum sensitivity 14 gram/year ¡î Unit dimensions 155mm¡Á45mm¡Á36mm Warm-up time 6 seconds ¡î Battery life Approx. 50hours Response time Instantaneous
Applications: Detect leaks in air-conditionings, freezing systems and so on. It will respond to ALL halogenated (contains Chlorine of Fluorine) refrigerants. This includes, but is not limited to: CFCs R12, R11, R500, R503etc. HCFCs R22, R123, R124, R502etc. HFCs R34a, R404a, R125etc Detect ethylene oxide gas of medical instruments Detect SF-6 in high voltage switch Detect most gases that contain Chlorine, Fluorine, and Bromine (halogen gases) Detect cleaning agents used in dry cleaning applications such as perchloroethyl Gross Weight: 263.5G/PC Packing: 56 PCS/CTN Measurement of the carton: 57¡Á36¡Á39cm ¡¡ |