As
we all know, the surface tension is to determine the liquid nature
principles of solubility , wetting, bubbling, coating and permeability.
People often analysis surface tension of a given liquid , and then study
the physical representation compared to other liquids or solids. This
study is the basic means of quality control in the process of
industrialization.
BZY-1 series of Automatic surface tension meter It provides a perfect
solution for customers on the surface tension . It is the perfect
‘linear’, fully able to detect changes due to existence of solution time
changes or surfactant. Moreover, the scope of its application will be
more widely used due to users’ reasonable and smart use.
Instrument features:Compared with other surface tension meter, BZY
series of surface tension meter including but not limited to the
following advantages:
² Automatic measurement,reduce human error to a minimum;
² Automatic reading of surface tension balance value;
² One key to reset(any numberbetween0-400mN),absolutely correct;
² One key to calibrate,with standard weights attached,rapidly and
accurately;
² The platinum plate method,fully comply with the requirement of basic
principle of Wilhelmy platinum plate , so as to provide possibility of
measuring under the following environment:
l Changes of surface tension due to the presence of surfactants value
l The measurement of high viscosity liquids (automatically read balance
value)
l Interfacial tension is not dissolved between two kinds of liquid, such
as oil and water.
² Sensor has sensitive response, high accuracy, in order to provide
possibility of excellent repeatability and comparability of data .
² Simple operation,without the need for any external computer control
² small machine error, more effective control of all kinds of errors in
testing process
² sample temperature cup , sample temperature detection device and the
external thermostatic bath can be chosen
BZY-1(or BZY-2)Technical indicators:
Measurement |
Platinum plate method |
Measuring Range
(mN/m) |
0-400mN/m
(or 0-200mN/m) |
Minimum
Resolution(mN/m |
0.1mN/m (or
0.01mN/m) |
Standard Error (mN/m)
( second
distilled water at 20℃ |
±0.1mN/m
(or ±0.02mN/m)
(Twice distilled water at 20℃) |
Repeatability (mN/m) |
±0.1mN/m (or
±0.02mN/m) (Twice distilled water at 20℃) |
Display |
LCD |
Reading time |
Usually
3-5seconds |
Power Supply |
AC220V |
Control |
CNC-button |
Temperature range |
According to
the external thermostatic bath(option): -0℃ ∽ 110℃ |
note:1mN/m=1dyne/cm |