pH/ISE Meter

 

Home     About us     Products    Contact us     Distributors  

 pH/ISE Meter

MP523 pH/ISE Meter
The fourth generation electrochemical meter, one of MP500 Series. It is the high precision pH + ISE Double-Parameter measurement meter which is suitable for precisIon measurement research and quality control
Equips two pH electrodes: one is plastic 3-in-1 pH electrode and the other one is 2503 glass pH electrode, which is suitable for high precision measurement.
There are 10 kinds of common ions can be selected in the ion concentration measuring mode, user also can self-define other ions.
Can switch 4 kinds of concentration unit : pX, mol/L, mg/L and ppm
Equips Intelligent stirrer, flexible electrode holder and brief operation instruction, more convenient for using
Instrument Rating: pH:0.001;ISE: 0.01More

mp523-ph-ise-meter.jpg
 

pH
Measuring range
Resolution
Accuracy
Input current
Input impendance
Stability
Temp. compensation range
(-1.999 ~ 19.999)pH
0.1/0.01/0.001 pH
Meter:±0.002 pH, connect meter with electrode:±0.01pH
≤1×10-12 A
≥3×1012 Ω
±0.002 pH/3h
(0 to 100) ℃(automatic or manual)
mV
Measuring range(mV/ORP/EH)
Resolution
Accuracy
-1999.9mV ~ 0 ~ 1999.9mV
0.1mV
±0.03% FS
Ion Concentration
Measuring range
Display unit
Accuracy
Temp. compensation range
0.00 ~ 14.00 pX
pX、mol/L、mg/L、ppm
Meter:±0.5 % reading(monovalent), ±1.0 % reading (bivalent)
0 to 60 ℃(automatic or manual)
Temperature
Measuring range
Resolution
Accuracy
-10℃~ 110℃
0.1℃
5~ 60℃range:±0.4℃  other range:±0.8℃
Other Technical Parameters:
Data storage
Storage content
 
Power
Communication connector
Size and weight
Quality and safety certification
300 groups
Measuring value series number, measuring value, temperature, ATC or MTC state, measuring date and time
DC9V/300mA
RS232
160 × 190 × 70mm/880g
ISO9001:2008, CE and CMC
Working Condition
Environment temperature
Environmental humidity
IP rating
5 ~ 35 ℃(0.01grade) 15 ~ 30 ℃(0.001grade)
≤75%
IP54 Dustproof and waterproof



MP517 Sodion Ion Meter
The fourth generation electrochemical meter, one of MP500 Series. It is suitable for measuring low Sodium ions concentration.
Sodium electrode range : 1~7 pNa (10-1~10-7 mol/L)
Equips sodion electrode, reference electrode and temperature electrode.
Instrument Rating: 0.01More

mp517-sodion-ion-meter.jpg
● Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function setting and self-diagnose etc.
● There are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode.
● Sodium electrode range : 1~7 pNa (10-1~10-7 mol/L)
● Equips sodion electrode, reference electrode and temperature electrode.
● Can switch 4 kinds of concentration unit : pX, mol/L, mg/L and ppm
●Meter has the only product serial number.
● Dustproof and waterproof meter meets IP54 standards. All sockets are seal protected by the silica gel caps.



MP518 Calcium Ion Meter
The fourth generation electrochemical meter, one of MP500 Series. It is suitable for measuring Calcium ion concentration.
Calcium electrode range : 1~5 pCa (10-1~10-5 mol/L)
Equips Calcium ion combination electrode, and temperature electrode.
Instrument Rating: 0.01More

mp518-calcium-ion-meter.jpg
● Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function setting and self-diagnose etc.
●There are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode.
●Calcium electrode range : 1~5 pCa (10-1~10-5 mol/L)
●Equips Calcium ion combination electrode, and temperature electrode.
● Can switch 4 kinds of concentration unit : pX, mol/L, mg/L and ppm
● Meter has the only product serial number.
● Dustproof and waterproof meter meets IP54 standards. All sockets are seal protected by the silica gel caps.



MP519 Fluorine Ion Meter
The fourth generation electrochemical meter, one of MP500 Series. It is suitable for measuring fluorion concentration.
Fluorion electrode range : 1~6 pF (10-1~10-6 mol/L)
Equips fluorion electrode, reference electrode and temperature electrode.
Instrument Rating: 0.01More

mp519-fluorine-ion-meter.jpg
●Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function setting and self-diagnose etc.
●There are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode.
●Fluorion electrode range : 1~6 pF (10-1~10-6 mol/L)
● Equips fluorion electrode, reference electrode and temperature electrode.
●Can switch 4 kinds of concentration unit : pX, mol/L, mg/L and ppm
● Meter has the only product serial number.
● Dustproof and waterproof meter meets IP54 standards. All sockets are seal protected by the silica gel caps.



YD200 Lab. Water Hardness Meter
Meter for measurement of water hardness by electrode measurement method, easy to use and accurate result.
Avoid the shortcomings of traditional measurement method: complicated EDTA titration, colorimeter measurement method can only be applied in water of high hardness (the lower limit of measurement >50mg/L).
Measurement scope 0~10mmol/L(0~1000mg/L(CaCO3)).
Ability to switch among

YD200-lab-water-hardness-meter.jpg

●Benchtop meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion).
●Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use.
●Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage RS232 output, etc.
● Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler) and mg/L (Ca). Three options of three units: ºfH(France)、ºdH (Germany)and ºeH(UK) from WH-Link communication software.
●Equipped with B1、B2 and B3 calibration solution.
●Equipped with WH-Link communication software, connect testing data of meter to computer.
 

Water Hardness
Measuring range
 
 
 
Resolution
Accuracy
Temp. compensation
Calibration Solution
 
 
 
Calibration Mode
(0 ~ 10)mmol/L;        (0 ~ 401)mg/L(Ca);
(0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree);
(0 ~ 561)mg/L(CaO);    (0 ~ 56)ºdH(German Degree);
(0 ~ 20)mmol/L(Boiler);  (0 ~ 70)ºeH (England Degree)。
0.01 and 0.1 water hardness units
±5% FS
(5 ~ 50)℃((automatic))
B1 Calibration Solution — 2.00×10-2 mmol/L
B2 Calibration Solution — 2.00×10-1 mmol/L
B3 Calibration Solution — 2.00 mmol/L
(B3Calibration Solution also can be used for the soaking solution of electrode)
(a)B1/B2 Calibration—using B1 and B2 Calibration Solution,suitable for < 2.00×10-2 mmol/L low concentration water quality,for example, boiler
water.
(b)Calibration—using B2 and B3 Calibration Solution,suitable forgeneral water quality.
Temperature
Measuring range
Resolution
Accuracy
0 ~ 60℃
0.1℃
±0.5℃
Other Technical Parameter
Data storage
Content Storage
Communication Connector
Power
Dimension and weight
Quality and safe certificate
128 groups

serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way.

RS232
DC9V
(160×190×70)mm/750g
IISO9001:2000 and CE
working conditions
Ambient temperature
ambient humidity
(5~35)℃
≤85%RH


YD300 Portable Water Hardness Meter
● Meter for measurement of water hardness by electrode measurement method, easy to use and accurate result.
● Avoid the shortcomings of traditional measurement method: complicated EDTA titration, colorimeter measurement method can only be applied in water of high hardness (the lower limit of measurement >50mg/L).
● Measurement scope 0~10mmol/L(0~1000mg/L(CaCO3)).
● Ability to switch among five units of water hardness.More

yd300-portable-water-hardness-meter.jpg

●Portable meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion).
● Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use.
●Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage, low voltage display, etc.
● Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler), mg/L (Ca). Three options of three units : ºfH(France)、ºdH (Germany)and ºeH(UK)from WH-Link communication software.
● Equipped with B1、B2 and B3 calibration solution.
● IP57 waterproof rating, equipped with portable case, calibration solution and other accessories.

 

Water Hardness
Measuring range
 
 
 
Resolution
Accuracy
Temp. compensation
Calibration Solution
 
 
 
Calibration Mode
(0 ~ 10)mmol/L;        (0 ~ 401)mg/L(Ca);
(0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree);
(0 ~ 561)mg/L(CaO);    (0 ~ 56)ºdH(German Degree);
(0 ~ 20)mmol/L(Boiler);  (0 ~ 70)ºeH (England Degree)。
0.01 and 0.1 water hardness units
±5% FS
(5 ~ 50)℃((automatic))
B1 Calibration Solution — 2.00×10-2 mmol/L
B2 Calibration Solution — 2.00×10-1 mmol/L
B3 Calibration Solution — 2.00 mmol/L
(B3Calibration Solution also can be used for the soaking solution of electrode)
(a)B1/B2 Calibration—using B1 and B2 Calibration Solution,suitable for < 2.00×10-2 mmol/L low concentration water quality,for example, boiler
water.
(b)Calibration—using B2 and B3 Calibration Solution,suitable forgeneral water quality.
Temperature
Measuring range
Resolution
Accuracy
0 ~ 60℃
0.1℃
±0.5℃
Other Technical Parameter
Data storage
Content Storage
 

Power

Dimension and weight
Quality & safecertificate
99 groups

serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way.

Two AA cells(1.5V×2)
Meter:(65×120×31)mm/180g; Carry Case: (255×210×50)mm/790g
IISO9001:2000 and CE
working conditions
Ambient temperature
ambient humidity
(5~35)℃